Brocade Communications Systems StorageWorks 4400 - Enterprise Virtual Array Manuale Utente

Navigare online o scaricare Manuale Utente per Switch di rete Brocade Communications Systems StorageWorks 4400 - Enterprise Virtual Array. Implementing disaster tolerant and disaster recovery Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 23
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 0
Table of contents
Introduction ......................................................................................................................................... 2
Solution configuration .......................................................................................................................... 3
Test scenario ................................................................................................................................... 3
WFEs .......................................................................................................................................... 3
Index servers ................................................................................................................................ 3
SQL Server back end .................................................................................................................... 4
Test environment .............................................................................................................................. 4
Implementing data replication with Continuous Access EVA .................................................................... 10
Verify EVA setup ........................................................................................................................ 10
Set the fibre channel switch configuration settings for replication ...................................................... 11
Creating fabrics and zones.......................................................................................................... 11
Create data replication group(s) ................................................................................................... 11
Write mode option ..................................................................................................................... 13
Failsafe mode option .................................................................................................................. 13
Replication log options ................................................................................................................ 13
Normalization ............................................................................................................................ 13
Present the destination virtual disks ............................................................................................... 14
Implementing disaster tolerance with Cluster Extension EVA .................................................................... 14
Prerequisites .............................................................................................................................. 14
Disaster tolerance scenarios ................................................................................................................ 17
Site A cluster node failure ............................................................................................................... 17
Site A all node failure ..................................................................................................................... 17
ISL link failure ................................................................................................................................ 18
Site A access to storage failure ........................................................................................................ 19
Site A site failure ............................................................................................................................ 19
Failover during DR group resynchronization ...................................................................................... 19
Disaster recovery ............................................................................................................................... 20
Cluster node recovery (failback) ....................................................................................................... 20
ISL link connectivity resumed ............................................................................................................ 21
Site A access to storage resumed ..................................................................................................... 21
Site A failback ............................................................................................................................... 21
Failback during resynchronization .................................................................................................... 21
Summary of key findings .................................................................................................................... 22
Conclusion ........................................................................................................................................ 22
For more information .......................................................................................................................... 23
Call to action .................................................................................................................................... 23
Implementing disaster tolerant and disaster
recovery solutions for Microsoft SharePoint using
HP storage replication technologies
(Part 1)
Vedere la pagina 0
1 2 3 4 5 6 ... 22 23

Sommario

Pagina 1 - (Part 1)

Table of contents Introduction ...

Pagina 2 - Introduction

10 Table 4. SharePoint Server LUN mapping Disk drive letter or mount point Data type Disk group LUN size (GB) RAID level E:\ Presented to Index Serv

Pagina 3 - Solution configuration

11 Figure 3 shows where HP Continuous Access EVA license are installed using Command View EVA. Figure 3. HP Continuous Access EVA license installati

Pagina 4 - Test environment

12 In our test environment, a second instance of SQL Server 2008 is used to store half of the SharePoint content databases. By dividing the SharePoin

Pagina 5

13 Write mode option The DR Groups write mode is specified during the creation of a DR group. The options are synchronous and asynchronous. Testing i

Pagina 6 - 1 4 7 10

14 Figure 5. Add member to a DR group Present the destination virtual disks Once all the Vdisks are added to the DR group, the Vdisk replicas on

Pagina 7

15 Figure 6. Fibre Channel zoning example  After ensuring that the prerequisites are met and installing the CLX software on each SQL Server clus

Pagina 8 - 12.2(50)SE

16  After adding the CLX cluster resource, select the resource properties and configure it as shown in Figure 8. Figure 8. Configure CLX cluster

Pagina 9

17 Disaster tolerance scenarios This section describes the disaster tolerance scenarios used in testing, including definitions of configurable option

Pagina 10

18 In the test environment, WFEs on Site B are configured as SharePoint search query servers. A copy of the search index is replicated to each WFE, i

Pagina 11

19 Site A access to storage failure When shared storage resources being used by SQL Server become unavailable, a cluster failover event is triggered.

Pagina 12 - Figure 4. Create a DR group

2 Introduction Microsoft Office SharePoint Server (MOSS) is Microsoft’s fastest growing technology. Companies of all sizes are leveraging its remarka

Pagina 13

20 Figure 11. Failover/Failback resource property Disaster recovery Cluster node recovery (failback) Because there is no disruption to the SAN or

Pagina 14

21 ISL link connectivity resumed When an ISL link is restored, data replication automatically resumes if the suspend on links down parameter is disa

Pagina 15

22 Summary of key findings The following is summary of key findings discovered during testing.  Appropriate sizing, including hardware and replicat

Pagina 16

23 For more information  Disaster-proof solutions from HP http://h71028.www7.hp.com/enterprise/cache/523434-0-0-0-121.html  Microsoft Storag

Pagina 17 - Disaster tolerance scenarios

3 Solution configuration Test scenario To demonstrate the capability of HP disaster tolerance and disaster recovery solution, testing is performed on

Pagina 18 - ISL link failure

4 information about alternative methods, see “Plan and Configure availability within an Office SharePoint Server farm.” During testing, recrawling co

Pagina 19 - Site A site failure

5 o HP provides guidance for implementing virtualization in Sharepoint environments. For more information, see the Best practices for deploying Micr

Pagina 20 - Disaster recovery

6 Figure 2 shows a physical view of hardware used in the dual site test environment. Figure 2. Physical view of the dual site test environment UIDH

Pagina 21 - Site A failback

7 Table 1 describes the hardware, software, and firmware versions used in testing. Table 1. Hardware and software version matrix Hs Hardware Softw

Pagina 22 - Summary of key findings

8 Hs Hardware Software/firmware version FC Switches: Brocade 8/24 SAN Switch Power Pack for HP c-Class BladeSystem switches (8), (4 per site)

Pagina 23 - Call to action

9 Table 3. SQL Server LUN mapping Disk drive letter or mount point Data type Disk group LUN size (GB) RAID level F:\ SQL install path SQL1 MOSS 100

Commenti su questo manuale

Nessun commento